Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Ann Intern Med ; 176(3): 289-297, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36716451

RESUMO

BACKGROUND: Studies have shown that magnetic resonance imaging (MRI) does not have clinically important effects on the device parameters of non-MRI-conditional implantable cardioverter-defibrillators (ICDs). However, data on non-MRI-conditional ICD detection and treatment of arrhythmias after MRI are limited. OBJECTIVE: To examine if non-MRI-conditional ICDs have preserved shock function of arrhythmias after MRI. DESIGN: Prospective cohort study. (ClinicalTrials.gov: NCT01130896). SETTING: 1 center in the United States. PATIENTS: 629 patients with non-MRI-conditional ICDs enrolled consecutively between February 2003 and January 2015. INTERVENTIONS: 813 total MRI examinations at a magnetic field strength of 1.5 Tesla using a prespecified safety protocol. MEASUREMENTS: Implantable cardioverter-defibrillator interrogations were collected after MRI. Clinical outcomes included arrhythmia detection and treatment, generator or lead exchanges, adverse events, and death. RESULTS: During a median follow-up of 2.2 years from MRI to latest available ICD interrogation before generator or lead exchange in 536 patients, 4177 arrhythmia episodes were detected, and 97 patients received ICD shocks. Sixty-one patients (10% of total) had 130 spontaneous ventricular tachycardia or fibrillation events terminated by ICD shocks. A total of 210 patients (33% of total) are known to have died (median, 1.7 years from MRI to death); 3 had cardiac arrhythmia deaths where shocks were indicated without direct evidence of device dysfunction. LIMITATIONS: Data were acquired at a single center and may not be generalizable to other clinical settings and MRI facilities. Implantable cardioverter-defibrillator interrogations were not available for a subset of patients; adjudication of cause of death relied solely on death certificate data in a subset. CONCLUSION: Non-MRI-conditional ICDs appropriately treated detected tachyarrhythmias after MRI. No serious adverse effects on device function were reported after MRI. PRIMARY FUNDING SOURCE: Johns Hopkins University and National Institutes of Health.


Assuntos
Desfibriladores Implantáveis , Humanos , Arritmias Cardíacas/terapia , Causas de Morte , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis/efeitos adversos , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Estudos Prospectivos , Resultado do Tratamento
2.
Radiology ; 295(2): 307-313, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32125255

RESUMO

Background The risks associated with MRI in individuals who have implanted cardiac devices are thought to arise from the interaction between the implanted device and static, gradient, and radiofrequency magnetic fields. Purpose To determine the relationship between the peak whole-body averaged specific absorption rate (SAR) and change in magnetic field per unit time (dB/dt), maximum specific energy dose, imaging region, and implanted cardiac device characteristics and their function in patients undergoing MRI. Materials and Methods This prospective observational cohort study was conducted from October 16, 2003, to January 22, 2015 (https://ClinicalTrials.gov, NCT01130896). Any individual with an implanted cardiac device who was referred for MRI was included. Clinical MRI protocols without SAR restriction were used. Exclusion criteria were newly implanted leads, abandoned or epicardial leads, and dependence on a pacemaker with an implantable cardioverter defibrillator without asynchronous pacing capability. For each MRI pulse sequence, the calculated whole-body values for SAR, dB/dt, and scan duration were collected. Atrial and ventricular sensing, lead impedance, and capture threshold were evaluated before and immediately after (within 10 minutes) completion of each MRI examination. Generalized estimating equations with Gaussian family, identity link, and an exchangeable working correlation matrix were used for statistical analysis. Results A total of 2028 MRI examinations were performed in 1464 study participants with 2755 device leads (mean age, 67 years ± 15 [standard deviation]; 930 men [64%]). There was no evidence of an association between radiofrequency energy deposition, dB/dt, or scan duration and changes in device parameters. Thoracic MRI was associated with decreased battery voltage immediately after MRI (ß = -0.008 V, P < .001). Additionally, right ventricular (RV) lead length was associated with decreased RV sensing (ß = -0.012 mV, P = .05) and reduced RV capture threshold (ß = -0.002 V, P < .01) immediately after MRI. Conclusion There was no evidence of an association between MRI parameters that characterize patient exposure to radiofrequency energy and changes in device and lead parameters immediately after MRI. Nevertheless, device interrogation before and after MRI remains mandatory due to the potential for device reset and changes in lead or generator parameters. © RSNA, 2020 See also the editorial by Shellock in this issue.


Assuntos
Desfibriladores Implantáveis , Imageamento por Ressonância Magnética/métodos , Marca-Passo Artificial , Segurança do Paciente , Idoso , Protocolos Clínicos , Segurança de Equipamentos , Feminino , Humanos , Masculino , Estudos Prospectivos , Ondas de Rádio
5.
N Engl J Med ; 377(26): 2555-2564, 2017 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-29281579

RESUMO

BACKGROUND: Patients who have pacemakers or defibrillators are often denied the opportunity to undergo magnetic resonance imaging (MRI) because of safety concerns, unless the devices meet certain criteria specified by the Food and Drug Administration (termed "MRI-conditional" devices). METHODS: We performed a prospective, nonrandomized study to assess the safety of MRI at a magnetic field strength of 1.5 Tesla in 1509 patients who had a pacemaker (58%) or an implantable cardioverter-defibrillator (42%) that was not considered to be MRI-conditional (termed a "legacy" device). Overall, the patients underwent 2103 thoracic and nonthoracic MRI examinations that were deemed to be clinically necessary. The pacing mode was changed to asynchronous mode for pacing-dependent patients and to demand mode for other patients. Tachyarrhythmia functions were disabled. Outcome assessments included adverse events and changes in the variables that indicate lead and generator function and interaction with surrounding tissue (device parameters). RESULTS: No long-term clinically significant adverse events were reported. In nine MRI examinations (0.4%; 95% confidence interval, 0.2 to 0.7), the patient's device reset to a backup mode. The reset was transient in eight of the nine examinations. In one case, a pacemaker with less than 1 month left of battery life reset to ventricular inhibited pacing and could not be reprogrammed; the device was subsequently replaced. The most common notable change in device parameters (>50% change from baseline) immediately after MRI was a decrease in P-wave amplitude, which occurred in 1% of the patients. At long-term follow-up (results of which were available for 63% of the patients), the most common notable changes from baseline were decreases in P-wave amplitude (in 4% of the patients), increases in atrial capture threshold (4%), increases in right ventricular capture threshold (4%), and increases in left ventricular capture threshold (3%). The observed changes in lead parameters were not clinically significant and did not require device revision or reprogramming. CONCLUSIONS: We evaluated the safety of MRI, performed with the use of a prespecified safety protocol, in 1509 patients who had a legacy pacemaker or a legacy implantable cardioverter-defibrillator system. No long-term clinically significant adverse events were reported. (Funded by Johns Hopkins University and the National Institutes of Health; ClinicalTrials.gov number, NCT01130896 .).


Assuntos
Desfibriladores Implantáveis , Segurança de Equipamentos , Imageamento por Ressonância Magnética/efeitos adversos , Marca-Passo Artificial , Idoso , Fontes de Energia Elétrica , Falha de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
6.
Clin Med Insights Cardiol ; 9: 39-45, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26005361

RESUMO

AIMS: Recent studies have shown that several genetic variants near the PITX2 locus on chromosome 4q25 are associated with atrial fibrillation (AF). However, the mechanism that mediates this association remains unclear. Basic murine studies suggest that reduced PITX2 expression is associated with left atrial dilatation. We sought to examine the association between single nucleotide polymorphisms (SNPs) near PITX2 and left atrial size in patients with AF. METHODS: We prospectively enrolled 96 consecutive patients (mean age 60 ± 10 years, 72% male) with drug-resistant AF (57% paroxysmal, 38% persistent, and 5% long-standing persistent) who underwent catheter ablation. Following DNA extraction from blood obtained pre-operatively, SNPs rs10033464 and rs2200733 were genotyped using the Sequenom MassARRAY. Left atrial volume (LAV) was determined using three-dimensional imaging (CT or MRI prior to first ablation) and by investigators blinded to genotype results. RESULTS: The minor allele frequencies at SNPs rs10033464 and rs2200733 were 0.14 and 0.25, respectively. Using multivariable linear regression, homozygosity for the minor allele at rs10033464 (recessive model) was independently associated with larger LAV (P = 0.002) after adjustment for age, gender, BMI, height, type, and duration of AF, left ventricular ejection fraction, history of hypertension, valve disease, and antiarrhythmic drug use. The strength of the association was reconfirmed in a bootstrap study with 1000 resamplings. In contrast, no association was found between rs2200733 variant alleles and LAV. CONCLUSION: SNP rs10033464 near the PITX2 locus on 4q25 is associated with LAV. Left atrial dilatation may mediate the association of common variants at 4q25 with AF.

7.
Circ Arrhythm Electrophysiol ; 6(6): 1139-47, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24235267

RESUMO

BACKGROUND: The association of local electrogram features with scar morphology and distribution in nonischemic cardiomyopathy has not been investigated. We aimed to quantify the association of scar on late gadolinium-enhanced cardiac magnetic resonance with local electrograms and ventricular tachycardia circuit sites in patients with nonischemic cardiomyopathy. METHODS AND RESULTS: Fifteen patients with nonischemic cardiomyopathy underwent late gadolinium-enhanced cardiac magnetic resonance before ventricular tachycardia ablation. The transmural extent and intramural types (endocardial, midwall, epicardial, patchy, transmural) of scar were measured in late gadolinium-enhanced cardiac magnetic resonance short-axis planes. Electroanatomic map points were registered to late gadolinium-enhanced cardiac magnetic resonance images. Myocardial wall thickness, scar transmurality, and intramural scar types were independently associated with electrogram amplitude, duration, and deflections in linear mixed-effects multivariable models, clustered by patient. Fractionated and isolated potentials were more likely to be observed in regions with higher scar transmurality (P<0.0001 by ANOVA) and in regions with patchy scar (versus endocardial, midwall, epicardial scar; P<0.05 by ANOVA). Most ventricular tachycardia circuit sites were located in scar with >25% scar transmurality. CONCLUSIONS: Electrogram features are associated with scar morphology and distribution in patients with nonischemic cardiomyopathy. Previous knowledge of electrogram image associations may optimize procedural strategies including the decision to obtain epicardial access.


Assuntos
Cardiomiopatias/patologia , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Taquicardia Ventricular/patologia , Taquicardia Ventricular/fisiopatologia , Adulto , Cardiomiopatias/complicações , Cardiomiopatias/fisiopatologia , Eletrocardiografia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/complicações
8.
Circ Arrhythm Electrophysiol ; 5(6): 1081-90, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23149263

RESUMO

BACKGROUND: The association of scar on late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) with local electrograms on electroanatomic mapping has been investigated. We aimed to quantify these associations to gain insights regarding LGE-CMR image characteristics of tissues and critical sites that support postinfarct ventricular tachycardia (VT). METHODS AND RESULTS: LGE-CMR was performed in 23 patients with ischemic cardiomyopathy before VT ablation. Left ventricular wall thickness and postinfarct scar thickness were measured in each of 20 sectors per LGE-CMR short-axis plane. Electroanatomic mapping points were retrospectively registered to the corresponding LGE-CMR images. Multivariable regression analysis, clustered by patient, revealed significant associations among left ventricular wall thickness, postinfarct scar thickness, and intramural scar location on LGE-CMR, and local endocardial electrogram bipolar/unipolar voltage, duration, and deflections on electroanatomic mapping. Anteroposterior and septal/lateral scar localization was also associated with bipolar and unipolar voltage. Antiarrhythmic drug use was associated with electrogram duration. Critical sites of postinfarct VT were associated with >25% scar transmurality, and slow conduction sites with >40 ms stimulus-QRS time were associated with >75% scar transmurality. CONCLUSIONS: Critical sites for maintenance of postinfarct VT are confined to areas with >25% scar transmurality. Our data provide insights into the structural substrates for delayed conduction and VT and may reduce procedural time devoted to substrate mapping, overcome limitations of invasive mapping because of sampling density, and enhance magnetic resonance-based ablation by feature extraction from complex images.


Assuntos
Técnicas Eletrofisiológicas Cardíacas , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/complicações , Miocárdio/patologia , Taquicardia Ventricular/fisiopatologia , Idoso , Ablação por Cateter , Cicatriz/patologia , Cicatriz/cirurgia , Gadolínio , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Análise de Regressão , Estudos Retrospectivos
9.
Ann Intern Med ; 155(7): 415-24, 2011 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-21969340

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) is avoided in most patients with implanted cardiac devices because of safety concerns. OBJECTIVE: To define the safety of a protocol for MRI at the commonly used magnetic strength of 1.5 T in patients with implanted cardiac devices. DESIGN: Prospective nonrandomized trial. (ClinicalTrials.gov registration number: NCT01130896) SETTING: One center in the United States (94% of examinations) and one in Israel. PATIENTS: 438 patients with devices (54% with pacemakers and 46% with defibrillators) who underwent 555 MRI studies. INTERVENTION: Pacing mode was changed to asynchronous for pacemaker-dependent patients and to demand for others. Tachyarrhythmia functions were disabled. Blood pressure, electrocardiography, oximetry, and symptoms were monitored by a nurse with experience in cardiac life support and device programming who had immediate backup from an electrophysiologist. MEASUREMENTS: Activation or inhibition of pacing, symptoms, and device variables. RESULTS: In 3 patients (0.7% [95% CI, 0% to 1.5%]), the device reverted to a transient back-up programming mode without long-term effects. Right ventricular (RV) sensing (median change, 0 mV [interquartile range {IQR}, -0.7 to 0 V]) and atrial and right and left ventricular lead impedances (median change, -2 Ω [IQR, -13 to 0 Ω], -4 Ω [IQR, -16 to 0 Ω], and -11 Ω [IQR, -40 to 0 Ω], respectively) were reduced immediately after MRI. At long-term follow-up (61% of patients), decreased RV sensing (median, 0 mV, [IQR, -1.1 to 0.3 mV]), decreased RV lead impedance (median, -3 Ω, [IQR, -29 to 15 Ω]), increased RV capture threshold (median, 0 V, IQR, [0 to 0.2 Ω]), and decreased battery voltage (median, -0.01 V, IQR, -0.04 to 0 V) were noted. The observed changes did not require device revision or reprogramming. LIMITATIONS: Not all available cardiac devices have been tested. Long-term in-person or telephone follow-up was unavailable in 43 patients (10%), and some data were missing. Those with missing long-term capture threshold data had higher baseline right atrial and right ventricular capture thresholds and were more likely to have undergone thoracic imaging. Defibrillation threshold testing and random assignment to a control group were not performed. CONCLUSION: With appropriate precautions, MRI can be done safely in patients with selected cardiac devices. Because changes in device variables and programming may occur, electrophysiologic monitoring during MRI is essential.


Assuntos
Desfibriladores Implantáveis , Imageamento por Ressonância Magnética/métodos , Marca-Passo Artificial , Idoso , Protocolos Clínicos , Contraindicações , Eletrofisiologia , Desenho de Equipamento , Falha de Equipamento , Feminino , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Estudos Prospectivos , Software
10.
Circ Cardiovasc Imaging ; 4(6): 662-70, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21946701

RESUMO

BACKGROUND: The safety and clinical utility of MRI at 1.5 T in patients with cardiac implantable devices such as pacemakers (PM) and implantable cardioverter-defibrillators (ICD) have been reported. This study aims to evaluate the extent of artifacts on cardiac magnetic resonance (CMR) in patients with PM and ICD (PM/ICD). METHODS AND RESULTS: A total of 71 CMR studies were performed with an established safety protocol in patients with prepectoral PM/ICD. The artifact area around the PM/ICD generator was measured in all short-axis (SA), horizontal (HLA), and vertical long-axis (VLA) SSFP cine planes. The location and extent of artifacts were also assessed in all SA (20 sectors per plane), HLA, and VLA (6 sectors per plane) late gadolinium-enhanced CMR (LGE-CMR) planes. The artifact area on cine CMR was significantly larger with ICD versus PM generators in each plane (P<0.001, respectively). In patients with left-sided ICD or biventricular ICD systems, the percentages of sectors with any artifacts on LGE-CMR were 53.7%, 48.0%, and 49.2% in SA, HLA, and VLA planes, respectively. Patients with left-sided PM or right-sided PM/ICD had fewer artifacts. Anterior and apical regions were severely affected by artifact caused by left-sided PM/ICD generators. CONCLUSIONS: In contrast to patients with right-sided PM/ICD and left-sided PM, the anterior and apical left ventricle can be affected by susceptibility artifacts in patients with left-sided ICD. Artifact reduction methodologies will be necessary to improve the performance of CMR in patients with left sided ICD systems.


Assuntos
Artefatos , Desfibriladores Implantáveis/efeitos adversos , Imagem Cinética por Ressonância Magnética/métodos , Marca-Passo Artificial/efeitos adversos , Adulto , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Estudos de Coortes , Estudos de Avaliação como Assunto , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença
11.
Caribbean Health ; 4(5): 7-8, Oct. 2001.
Artigo em Inglês | MedCarib | ID: med-17073

RESUMO

Over the past 30 years, mortality from acute myocardial infarction (MI) has decreased substantially in developing countries. While this decline is attributed, in part to a reduction in coronary risk factors, some reports have identified improved theraputic management as being equally responsible for decline. Currently available treatment for patients presenting with ST segment elevation MI (MIs associated with complete occlusion of a coronary artery) includes the concomitant administration of aspirin ƒ-blockers, angiotensin-converting enzyme (ACE) inhibitors, and either thrombolytics or primary percutaneous transluminal angioplasty (PTCA) (AU)


Assuntos
Humanos , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/terapia , Terapia Trombolítica , Região do Caribe , Inibidores da Enzima Conversora de Angiotensina
12.
Caribbean Health ; 4(3): 9-10, June 2001. ilus
Artigo em Inglês | MedCarib | ID: med-17066

RESUMO

Recent technological advances in resuscitation equipment and procedures have opened the door for some developing countries to consider implementing early defibrillation programmes. This is particularly true in the Caribbean, where urbanisation is rapidly altering the nature of health problems, and public expectations of healthcare delivery is rapidly rising. However before an SCD victim in the Caribbean can expect to be rescued from a cardiac arrest there is much work to be done. 'Core ACLS' courses that emphasise the critical aspects of ACLS, coupled with widespread teaching programmes aimed at educating the general public about cardiovascular resuscitation, should be initiated. Before full advantage can be taken of recent technological advances, and emergency medical systems can become a reality in the Caribbean, a comprehensive approach to the introduction of resuscitative practices should be considered (AU)


Assuntos
Humanos , Idoso , Cardioversão Elétrica , Morte Súbita Cardíaca , Parada Cardíaca , Serviços Médicos de Emergência , Região do Caribe
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...